Description:
The hydraulic SAE counter adapter forms the mating side of an SAE flange connection. Selecting the correct adapter requires matching the flange series, nominal size, sealing face, and pipe-end dimensions.
Code 61 and Code 62 identify different flange series. Working pressure should be checked against the specification for the selected model and complete assembly.
Send Topa your drawing, mating component details, and required quantity for product selection and quotation.
Features and Benefits:
• Mating face for the flange sealing connection
• Compact profile for hydraulic piping connections
• Selection based on flange interface and pipe dimensions
• Clearly defined component requirements for ordering and assembly
Categories: SAE, Flange, Code 62, Code61, Carbon steel, adapter
MAX. W.P (kg/cm²) | Size | Type | Dimensions | |||||||
A | B | C | D | E | F | O-ring | Wt Kg | |||
SERIE 3000 | ||||||||||
345 | 1/2″ | SFS301STA21 | 21.5 | 13 | 30.2 | 24 | 41 | 6.73 | 4075 | 0.08 |
345 | 3/4″ | SFS302STA28 | 28 | 19 | 38.1 | 32 | 50 | 6.73 | 4100 | 0.16 |
345 | 1″ | SFS303STA34 | 34 | 25 | 44.4 | 38 | 50 | 8 | 4131 | 0.23 |
276 | 1″1/4 | SFS304STA42 | 42.8 | 32 | 50.8 | 43 | 55 | 8 | 4150 | 0.3 |
207 | 1″1/2 | SFS305STA48 | 48.6 | 38 | 60.3 | 50 | 57 | 8 | 4187 | 0.4 |
207 | 2″ | SFS306STA61 | 61 | 51 | 71.4 | 62 | 57 | 9.53 | 4225 | 0.5 |
SERIE 6000 | ||||||||||
414 | 1/2″ | SFS601STA21 | 21.5 | 13 | 31.8 | 24 | 34 | 7.75 | 4075 | 0.08 |
414 | 3/4″ | SFS602STA28 | 28 | 19 | 41.3 | 32 | 38 | 8.76 | 4100 | 0.15 |
414 | 1″ | SFS603STA34 | 34 | 25 | 47.6 | 38 | 40 | 9.53 | 4131 | 0.23 |
414 | 1″1/4 | SFS604STA42 | 42.8 | 32 | 54 | 44 | 45 | 10.29 | 4150 | 0.3 |
414 | 1″1/2 | SFS605STA48 | 48.6 | 38 | 63.5 | 51 | 50 | 12.57 | 4187 | 0.5 |
414 | 2″ | SFS606STA61 | 61 | 51 | 79.4 | 67 | 58 | 12.57 | 4225 | 0.8 |
Start by identifying the mating flange component and its interface series. Compare the sealing face and flange dimensions, then check the pipe end against the pipe used in your assembly.
The operating conditions also affect selection. Use the approved working pressure for the specific model and consider the complete connection, including the pipe, seals, clamps, and fasteners. A Code 61 or Code 62 designation alone does not establish the rating of the finished assembly.
Provide the following information with your request:
Flange series and nominal size
Existing part number or drawing
Mating component and sealing-face details
Pipe outside diameter and wall thickness
Working pressure and expected pressure peaks
Hydraulic fluid and operating temperature
Required material and surface condition
Quantity by part number